<LOGO>
FM Transmitter Measurement Report
Created: 2025-04-29 21-36-46
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
96.90 MHz 5/5, 58 dBuV VOLTAGE
Pilot RDS Phase Difference
7.1 kHz 3.6 kHz -72 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
11 kHz 74 kHz 10100 2,9010
Modulation Power
Limit Measuring Tolerance
10,0 dBr 0,2 dBr
MIN AVE MAX % above 10,2 dBr
6,7 dBr 8,22 dBr 8,9 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"VOLTAGE " FE45 10 (Pop M) 1 0 0 5 21:36, 29.04.2025
RT
"VOLTAGE - Addictive Radio "
AF EON
96.9, 102.9 MHz -
FM Scope Station: 96.90 MHz, signal: 5/5 (57 dBuV) Max at: 74 kHz MIN: 11 kHz % above 76 kHz: 2,9010 Acquired: 2025/04/29 21:35:43 Total samples: 10100 Equivalent time: 0:08:25 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 1000 2000 3000
FM Scope MAX: 8,9 dBr MIN: 6,7 dBr AVE: 8,22 dBr % above 10,2 dBr: 0,0 Last value: 6,7 dBr (2025/04/29 21:35:42) Station: 96.90 MHz, signal: 5/5 (57 dBuV) 21:29 21:30 21:31 21:32 21:33 21:34 21:35 0 50 100 Dev. MAX [kHz] 0 5 Pm [dBr] 0 5 Signal Quality